Weak flow or low pressure can be measured and traced by Proper Plumbing London anywhere in Greater London. Weekday plumbing is £110 an hour with a one hour minimum, and quotes are free.

Pressure is the push in the pipe when little is moving; flow is how much water arrives when a tap is open. A system can read well on a gauge and still deliver poorly through a restriction, so both are measured before a remedy is chosen.
Measuring
- A gauge on an outside or appliance tap, with everything closed, gives static pressure.
- The same gauge with another outlet running shows how far pressure falls.
- A measuring jug and a timer give flow at each outlet.
- Readings at different times of day show whether the street supply varies.
Narrowing the cause
| Pattern | Start with |
|---|---|
| Every mains outlet weak | Stop valves, supply pipe, company supply |
| Only hot weak | Cylinder feed, hot branch, appliance |
| Only upstairs weak | Tank height or static head |
| One outlet weak | Aerator, filter, hose, valve |
| Falls sharply when a second tap opens | Undersized or restricted pipe |
| Recent drop in the street | Neighbours and the water company |
Contact your water company about suspected supply problems outside the property. It can measure at the boundary and tell you the standard of service that applies.
Remedies
Remove restrictions. Open part-closed valves, clean strainers, replace valves that no longer open fully.
Renew pipe. A corroded or narrow supply limits everything after it. Larger bore helps flow but cannot raise the pressure delivered from the street.
Change the arrangement. Stored water with a pump, or a break tank and booster, can help where supply is genuinely limited. Space, noise, power and tank hygiene have to be accepted.
Control excess pressure. High pressure causes noise and strain, addressed with a reducing valve.
If a booster pump is the remedy
Regulation 5 makes prior notice and consent from the water company conditions of connecting to a supply pipe any booster or pump drawing above 12 litres a minute, whether directly or indirectly. The consent may carry conditions. See whether a pump may go on the main, booster sets in blocks of flats and a pump that keeps starting.
Work and testing
After any change, the same readings are taken at the same points so the difference is a measurement rather than an impression. Joints are checked at working pressure, tank refill rate is confirmed against demand and mixer temperature is rechecked, since altering one side upsets the balance between hot and cold.
Mixed hot and cold supplies
Showers and mixer taps behave badly when one side is much stronger than the other. The weaker side is overwhelmed, temperature drifts and water may push back across the valve. Measure each side separately before choosing a fitting, and note whether the cold feed to the shower shares a pipe with a toilet or washing machine. The remedy may be matching the supplies, adding a reducing valve and check valves, or selecting equipment designed for the available head.
Billing for this work
| Time | Rate |
|---|---|
| Weekday, 1 hour minimum | £110 per hour |
| Evening or weekend | from £140 per hour |
24/7 emergency visits: £110 an hour plus a £60 call-out on weekdays in the daytime, from £140 an hour plus £60 in the evening or at weekends. Booked jobs carry no call-out fee. Materials are extra and agreed first. VAT is not added. Quotation free. Rates verified 28 November 2026: billing detail.
What to send
Your readings, the affected outlets, the time of day, the property's floor level and photographs of the stop valve and tank. Use the contact form.
Related reading
Diagnosis starts with the difference between flow and pressure, telling gravity from mains supply, how a cold water system is laid out, direct and indirect systems and no cold water upstairs.
Supply-side limits are covered in signs of an undersized supply, low flow on a shared supply, pressure that changes overnight and the rules on pumping from the main.
At a glance
- Service
- Water pressure
- Area
- All of Greater London (service-area business, no showroom)
- Quote
- Free. Get the price in writing before work starts
- Phone
- 020 3961 8088
Questions
Will a bigger pipe increase pressure?
It can improve flow when the existing pipe is the restriction, but it does not raise the static pressure supplied from the street.
What is the difference between pressure and flow?
Pressure is the push in the pipe when little is moving. Flow is how much water arrives when a tap is open. Both are measured before choosing a remedy.
Is permission needed for a booster pump?
Above a draw of 12 litres a minute on a supply pipe, yes: the water company must receive notice and give consent first.