Unvented cylinder servicing, repair and replacement in Greater London is arranged by Proper Plumbing London and done only by G3 qualified engineers. Weekday time is £110 an hour, one hour minimum.

An unvented cylinder stores hot water at pressure straight from the main, with no loft tank or open vent. Only G3 qualified engineers fit, service, repair or replace one, with cylinder specialists available where needed.
Layers of protection
| Control | Job |
|---|---|
| Control thermostat | Holds the normal storage temperature |
| Energy cut-out | Stops the heat source if temperature rises too far |
| Temperature and pressure relief valve | Releases water as the last line of defence |
| Pressure reducing valve | Limits incoming pressure to the design value |
| Expansion vessel or internal air gap | Takes up expansion as water heats |
| Expansion relief valve | Opens if expansion pressure exceeds its setting |
| Tundish and discharge pipe | Shows a discharge and carries it away safely |
None of these may be capped, replaced with a different rating or bypassed. The Building Regulations requirements are described in Approved Document G.
What symptoms suggest
- Drip at the tundish as water heats: expansion has nowhere to go, often a flat vessel or lost air gap.
- Constant discharge: a debris-held or failed relief valve, or a faulty reducing valve.
- Poor flow at hot taps: blocked strainer, reducing valve fault or low incoming supply.
- No hot water: tripped cut-out, immersion or motorised valve fault. A tripped cut-out has a cause that must be found before reset.
- Damp casing: leaking boss, element seal or the vessel inside the jacket.
Annual service
The maker's schedule normally includes operating both relief valves, confirming they reseat, cleaning the line strainer, checking vessel pre-charge or restoring the air gap, testing thermostats and following the discharge route to its end. The result is written on the service record or benchmark log for the cylinder.
Replacement or new installation
Mains flow and pressure are measured to confirm the supply can serve the outlets. The floor must carry the filled weight, and the discharge pipe needs a continuous fall, correct size, suitable material and a safe visible termination. That route often decides where a cylinder can stand. New unvented systems over 15 litres are notifiable in England, either through a competent person scheme or building control.
If it is boiling or discharging hard
Where it is safe, cancel both heat inputs (immersion and boiler call), stand clear of hot discharge and find immediate help. Do not close, plug or tie any safety valve or pipe.
Billing for this work
| Time | Rate |
|---|---|
| Weekday, 1 hour minimum | £110 per hour |
| Evening or weekend | from £140 per hour |
24/7 emergency visits: £110 an hour plus a £60 call-out on weekdays in the daytime, from £140 an hour plus £60 in the evening or at weekends. Booked jobs carry no call-out fee. Materials are extra and agreed first. VAT is not added. Quotation free. Rates verified 28 November 2026: billing detail.
What to send
On the contact form, copy the details from the cylinder data plate, give the last service date and say whether heat comes from a boiler, an immersion or both. Picture the valve group, expansion vessel, tundish and the end of the discharge pipe. Email photographs to info@properplumbinglondon.co.uk after sending.
Related reading
Compare vented and other cylinder arrangements, check supply pressure and flow and read how a pressure reducing valve works.
At a glance
- Service
- Unvented cylinders
- Area
- All of Greater London (service-area business, no showroom)
- Quote
- Free. Get the price in writing before work starts
- Who does it
- Unvented work only by G3 qualified engineers
- Phone
- 020 3961 8088
Questions
Is water in the tundish ever normal?
A visible discharge means a safety or expansion valve is passing water. Treat it as a fault to be investigated, and if the water is very hot or flowing steadily, switch off the heat sources and get urgent help.
Can a safety valve on an unvented cylinder be capped?
No. Safety controls must never be capped, bypassed or replaced with a different rating, and a discharge pipe must never be plugged.
What does an annual service normally include?
Depending on the maker's schedule: operating both relief valves, cleaning the line strainer, checking the vessel charge or air gap, testing thermostats and following the discharge pipe to its end.