Proper Plumbing London arranges gas boiler repairs across Greater London, with gas work done only by Gas Safe registered engineers. Weekday gas time is £110 an hour; evenings and weekends start from £140.

A boiler that stops, locks out or heats badly is traced one system at a time: water, electricity, controls, gas and combustion, then the flue and condensate route. Gas side, combustion chamber and flue are restricted to Gas Safe registered engineers.
Gas smell overrides diagnosis: get out without operating switches or striking a light, then ring 0800 111 999, the National Gas Emergency Service, from the open air.
Starting from the symptom
| What you notice | Areas that are tested |
|---|---|
| Display blank | Power supply, fused spur, internal fuse, control board |
| Lockout soon after trying to light | Gas supply, ignition, flame sensing, flue or condensate |
| Hot water works, heating does not | Programmer, room thermostat, diverter or zone valve |
| Heating works, hot water is weak or swings | Flow sensor, diverter valve, scaled heat exchanger |
| Pressure falls repeatedly | System leak, expansion vessel, relief valve |
| Gurgling and a stop in freezing weather | Frozen or blocked condensate pipe |
| Rumbling as it heats | Scale, debris or poor circulation |
The same display can have different causes on different models, so the manufacturer's fault chart for that appliance is the reference.
Water side or gas side
Much of what shows up on a boiler starts outside it. A closed radiator circuit, a stalled pump or lost system pressure will shut down a sound appliance. Those are covered under central heating repairs. Where the fault sits inside the sealed or combustion parts, or involves the gas valve, burner, ignition or flue, the cover stays closed to anyone who is not on the register for that category of work. The Gas Safety (Installation and Use) Regulations require anyone working on a gas fitting to be competent to do so.
How a repair visit is structured
- Confirm the report: what the boiler did, any code, and what had changed beforehand.
- Check supply pressure, power and control demand before opening the appliance.
- Test the suspected part against the maker's stated values.
- Explain the finding, the part needed and whether replacing it is sensible for the age and condition of the boiler.
- Fit the part with its correct seals, then re-establish the water and gas joints.
What proves it is fixed
A boiler that lights once has not been proved. After work that disturbs the gas or combustion path, the engineer checks gas tightness at disturbed joints, operating pressure or heat input, combustion where the maker requires it, safety devices and the flue. Regulation 26 lists the checks owed after work on a gas appliance. Heating and hot water are then run separately, and again together.
Repair or replace
Parts availability, corrosion, repeated failures in different components and a failing heat exchanger all weigh towards replacement. One failed sensor on an otherwise sound appliance does not. Ask for both options in writing when the choice is close.
Warning signs that stop everything
Yellow or orange flames where blue is expected, soot or brown staining around the appliance, a sounding carbon monoxide alarm, or headaches and dizziness that ease away from home need action at once. Switch the appliance off, open doors and windows, get everyone out into fresh air and ring the National Gas Emergency Service on 0800 111 999. Seek medical advice promptly about any symptoms, and do not use the appliance again until a Gas Safe registered engineer has made it safe. The HSE page on carbon monoxide explains the warning signs.
Billing for gas work
| Gas engineer time | Rate |
|---|---|
| Gas work | £110 per hour |
| Gas work, evening or weekend | from £140 per hour |
24/7 emergency visits: £110 an hour plus a £60 call-out on weekdays in the daytime, from £140 an hour plus £60 in the evening or at weekends. Booked jobs carry no call-out fee. Materials are extra and agreed first. VAT is not added. Quotation free. Rates verified 28 November 2026: billing detail.
What to send
Give the make and model from the data label or front panel, the exact code, any gauge value and the conditions that trigger the fault on the contact form. A view of the boiler and the pipes below it helps; do not remove the case. Email photographs to info@properplumbinglondon.co.uk after sending.
Related reading
Water-side background is in the feed and expansion tank, condensate connections to waste and frozen waste pipes.
At a glance
- Service
- Boiler repair
- Area
- All of Greater London (service-area business, no showroom)
- Quote
- Free. Get the price in writing before work starts
- Who does it
- Gas work only by Gas Safe registered engineers
- Phone
- 020 3961 8088
Questions
Is a fault code enough to name the failed part?
No. A code says which condition the boiler detected. The cause may be the named component, its wiring, the water circuit or the gas supply, so it is tested before anything is changed.
What should I note when a boiler stops?
What it did, any code on the display, the pressure reading, whether heating, hot water or both are lost, and anything that changed beforehand.
Can a boiler stop because of a fault outside it?
Yes. A closed radiator circuit, a stalled pump or lost system pressure will shut down a sound appliance.