A stop tap that is seized, passing or leaking can be repaired or replaced by Proper Plumbing London across Greater London, at £110 an hour on weekdays with a one hour minimum. Quotes are free.

The main valve indoors is the control that shuts off incoming water to a property. It needs to turn, close completely and be reachable. One that fails any of these should be repaired or replaced before it is needed for something else.
Finding it
Search along the route of the incoming main: sink base unit, hall cupboard, floor hatch, street-facing wall, and in flats the shared riser. Thames Water describes where to look and how to use it. A second valve outside near the boundary may belong to the water company, so check before operating it.
Checking its condition
| Test | Result that needs attention |
|---|---|
| Turn gently clockwise | Will not move |
| Open the kitchen cold tap with valve closed | Water keeps running |
| Look at the spindle after reopening | Weeping gland |
| Inspect the body | Green or white crust, corrosion |
Do not force it. A snapped spindle can leave a home with no water or a leak that cannot be stopped. Many people open a valve fully and then back it off slightly so it is less likely to jam.
Repair or replace
A weeping gland can often be corrected at the packing nut or by renewing the seal. A valve that passes water, has damaged threads or is badly corroded is replaced. Schedule 2 of the Water Fittings Regulations requires a stop valve positioned so that premises can be shut off without cutting off others.
Holding back the water
The difficulty is that water must be stopped before the main valve can be removed. Options are the company's external valve, a shared building valve with notice to affected residents, or pipe freezing where the material and layout allow. Lead or old steel on the incoming side needs a suitable transition fitting and gentle handling.
The new valve is fitted in the correct flow direction, with the pipe supported so that operating the handle does not twist the joints. A drain cock just after it allows the internal pipework to be emptied. Where access is poor, moving the valve to a better position may be worthwhile.
Testing
- Close the new valve before the upstream supply is restored.
- Check the inlet joint under pressure.
- Open slowly and clear air from taps.
- Close fully and confirm the cold mains outlet stops.
- Check the spindle and both joints again after several operations.
- Check the meter with everything off, and label the location.
Flats and shared supplies
A flat may have more than one valve, and a riser valve may feed several homes. Confirm which one controls your outlets by closing it briefly with permission and checking the cold mains tap. Where no individual valve exists, fitting one means a shared shutdown arranged through the freeholder or agent. Keep the position clear of stored items and tell everyone in the home where it is. Shared shut-off points in blocks are dealt with under riser and communal valve replacement.
Billing for this work
| Time | Rate |
|---|---|
| Weekday, 1 hour minimum | £110 per hour |
| Evening or weekend | from £140 per hour |
24/7 emergency visits: £110 an hour plus a £60 call-out on weekdays in the daytime, from £140 an hour plus £60 in the evening or at weekends. Booked jobs carry no call-out fee. Materials are extra and agreed first. VAT is not added. Quotation free. Rates verified 28 November 2026: billing detail.
What to send
A photograph of the valve and incoming pipe, whether it turns, and whether you live in a flat with a managing agent. Use the contact form.
Related reading
Controls along the supply are covered under labelling valves, motorised shut-off valves, drain cock replacement, draining down and where the supply enters the house.
At a glance
- Service
- Stopcocks
- Area
- All of Greater London (service-area business, no showroom)
- Quote
- Free. Get the price in writing before work starts
- Phone
- 020 3961 8088
Questions
Which way does a stop valve close?
Clockwise closes a conventional stop valve. Turn it gently and do not use force if it resists.
Where is the inside stop valve usually found?
Start at the kitchen sink base unit, then try hall cupboards, floor hatches and the wall facing the street. In flats, check the shared riser.
Should a stiff stop valve be forced?
No. A snapped spindle can leave a home with no water or with a leak that cannot be stopped.