Waste pipes
A waste pipe can be extended or moved if the new run keeps an adequate fall to its discharge point, stays within length limits for its diameter, or is ventilated where it exceeds them. Check this before choosing where the sink, bath or appliance goes. The height available between the trap and the connection often settles the question.
When the work is needed
Kitchen layouts that move the sink to an island or another wall, a new utility cupboard, a basin added to a bedroom, a bath turned round, or a washing machine relocated.
Limits to design within
From Approved Document H, 2015 edition, for unventilated branches in England:
| Appliance | Pipe | Maximum length | Fall per metre |
|---|---|---|---|
| Sink or bath | 40 mm | 3 m | 18 to 90 mm |
| Sink or bath | 50 mm | 4 m | 18 to 90 mm |
| Washbasin | 32 mm | 1.7 m | 18 to 22 mm at that length; steeper only on shorter runs |
| Washbasin | 40 mm | 3 m | 18 to 44 mm |
A toilet branch is a separate case: the document prints 15 m in Table 2 and 6 m for a single WC in Diagram 3, and 6 m is the safer design limit.
Where a larger pipe than the trap is used to gain length, the document's diagram keeps the trap size and lengthens the trap tail by 50 mm before stepping up. Beyond these limits, the branch should be ventilated, which can include an air admittance valve. Fuller figures are on waste pipe sizes.
Extending a sink waste pipe: the fall
A 3 m run of 40 mm sink waste at the 18 mm per metre minimum drops 54 mm (3 × 18). The connection therefore has to sit at least 54 mm below the start of the run, before allowing for bends and fittings. Measure that height first.
If the existing run already misbehaves
Extending a run that is already struggling makes it worse. Note these first.
| What you notice now | Possible cause | Safe check |
|---|---|---|
| Gurgle from the trap as it empties | Air being pulled through the water seal: run too long, steep or undersized, or poor venting | Measure length, pipe size and drop |
| Smell after the appliance has been used | Seal lost, or a joint open to the drain | Look for water standing in the trap and for damp at joints |
| Slow emptying that returns after clearing | Sag, backfall or a build-up in a flat length | Put a level on each reachable length |
| Water rising in a second appliance | Shared branch too small, or a blockage downstream | Run one appliance at a time and watch the other |
Run water and look, but leave solvent joints and the stack alone. More on gurgling waste pipes.
What gets looked at
- Measured level of the existing connection against the new trap outlet
- Route obstacles: joists, steel, doorways, screed and fire-separating walls
- What else joins the branch or stack
- Where on the stack the connection falls. In single dwellings of up to three storeys, a branch should not enter lower than 450 mm above the invert of the bend at the foot
- Rodding access to any length that cannot be cleared by removing a trap
Route options
| Route | Advantage | Trade-off |
|---|---|---|
| Surface run behind units | Accessible, simple | Needs a cupboard or boxing, limited by height |
| Through the floor void | Hidden | Joist holes are restricted and fall is hard to keep |
| Out through a wall to a gully | Short on ground floors | External pipe needs support and weather protection |
| New or different stack connection | Solves long runs | More work at the stack, possibly shared |
| Pumped unit | Works where gravity cannot | Needs power and upkeep, and is not a like-for-like substitute |
Keep bends to a minimum and use large-radius ones. Confirm what a drain carries before connecting to it, and keep household waste out of rainwater pipes and surface water drains.
Building control
Part H of the Building Regulations covers sanitary pipework, including new and lengthened runs. A kitchen or bathroom that is part of an extension or conversion will normally sit within a wider application. Ask your building control body before work is covered up.
What changes the price
- Length, route and the amount of floor or wall to open
- Whether a venting solution is needed
- Solid floors that must be chased or built over
- Stack material, since cast iron takes more work than plastic
- Making good, which is best agreed in writing
Ask for a quote
Email a sketch with distances, floor type, photos of the present connection and the proposed position. Include the building programme if others are involved. Write up the details on the contact form and email the images.
Related reading
Design points for a new run are covered under the choice of bend, clip spacing, passing through an outside wall, combining waste pipes, joining different sizes and connecting at a soil pipe boss.
At a glance
- Service
- Extending or moving a waste pipe
- Area
- All of Greater London (service-area business, no showroom)
- Quote
- Free. Get the price in writing before work starts
- Phone
- 020 3961 8088
Questions
How far can I extend a sink waste?
For an unventilated sink branch, Approved Document H shows up to 3 m in 40 mm pipe or 4 m in 50 mm pipe, laid at 18 to 90 mm fall per metre. Longer runs need ventilation or another route.
Can I use 50 mm pipe to go further than 3 m?
For an unventilated sink or bath branch, Approved Document H shows up to 4 m in 50 mm pipe, still with a suitable fall. Keep the trap at its correct size.
Can a sink waste join a shower or basin waste?
Sometimes. A shared unventilated pipe has to be sized for the appliances it serves, and a poor junction can pull a trap seal or push water into the other fixture. Check the combined layout before connecting.
Air admittance valve or open vent?
A valve lets air in to relieve suction and can avoid a roof or wall penetration, but it needs access and ventilation and cannot let pressure out. The drains still need adequate venting.