Gas boiler replacement and new installation in Greater London is available through Proper Plumbing London, carried out only by Gas Safe registered engineers. Quotes are free and gas time is £110 an hour on weekdays.

A boiler replacement is a system design job with a gas connection in it. The appliance is chosen after the water supply, radiators, flue route and drainage have been measured. Only Gas Safe registered engineers install and commission it.
System type
| Type | How hot water is made | Suits |
|---|---|---|
| Combination | On demand through the boiler | Good mains flow, few outlets in use at once |
| System boiler | Stored in a cylinder, usually sealed circuit | Several bathrooms, space for a cylinder |
| Regular boiler | Stored in a cylinder, fed with loft tanks | Existing tank-fed systems being kept |
Changing from stored water to a combination boiler removes tanks and cylinder, but the incoming main has to deliver the hot flow on its own. Flow and pressure are measured at the property first. See water pressure.
Sizing
Heating output follows a room-by-room heat loss estimate that considers walls, windows, insulation and ventilation. Copying the old boiler's label repeats any earlier error. Gas pipe size is checked against the new appliance's demand and the length of run, as a larger boiler may starve on an old branch.
Flue, condensate and position
The flue terminal needs set clearances from openings, boundaries and neighbouring surfaces, given in the manufacturer's instructions and Approved Document J. Concealed flue runs need access for inspection. Condensing boilers produce mildly acidic water that must fall to a suitable drain; an exposed external run can freeze, so an internal route is preferred. In flats, ask whether the freeholder must approve a new terminal or wall opening.
Efficiency and controls
Approved Document L covers efficiency requirements in England for replacement heating, including time and temperature control and expectations for combination boilers. Which measures apply depends on the work, so ask for them to be listed in the quotation.
Sequence on site
- Confirm the isolation points, protect finishes and agree how long water and heating will be off.
- Remove the old appliance and seal anything left redundant.
- Clean the circuit to the maker's requirements before connecting, and fit a filter where specified.
- Mount the boiler, then run gas, water, flue, condensate and relief pipework.
- Fill, vent and dose inhibitor.
- Test gas tightness, commission, set the output and balance radiators.
Handover documents
A gas boiler installation in England is notifiable building work. A registered installer can normally self-certify under a competent person scheme, after which a compliance certificate follows; otherwise building control approval is needed. Keep the completed commissioning checklist, the manuals, control instructions and the warranty registration details. In England, requirement J3 of the Building Regulations calls for carbon monoxide warning where a fixed combustion appliance such as a boiler is installed in a dwelling, so agree the alarm and its position as part of the job.
Billing for gas work
| Gas engineer time | Rate |
|---|---|
| Gas work | £110 per hour |
| Gas work, evening or weekend | from £140 per hour |
24/7 emergency visits: £110 an hour plus a £60 call-out on weekdays in the daytime, from £140 an hour plus £60 in the evening or at weekends. Booked jobs carry no call-out fee. Materials are extra and agreed first. VAT is not added. Quotation free. Rates verified 28 November 2026: billing detail.
Getting a scope together
Say on the contact form how many bathrooms and radiators there are, where the present boiler and any cylinder sit, where the flue leaves the building and what you want to change. Useful pictures show the boiler, gas meter and outside wall. Email photographs to info@properplumbinglondon.co.uk after sending.
Related reading
Check the supply with a pressure and flow test, then read about condensate to waste, hard water and pipe sizing.
At a glance
- Service
- Boiler installation and replacement
- Area
- All of Greater London (service-area business, no showroom)
- Quote
- Free. Get the price in writing before work starts
- Who does it
- Gas work only by Gas Safe registered engineers
- Phone
- 020 3961 8088
Questions
Can the new boiler be larger just to be safe?
Bigger is not safer. An oversized boiler tends to cycle on and off for heating. Output is chosen from the building's heat loss and, for a combination boiler, the hot water flow wanted.
What is measured before a boiler is chosen?
The water supply, radiators, flue route and condensate drainage. Heating output follows a room-by-room heat loss estimate, and the gas pipe size is checked against the new appliance.
Is a new gas boiler notifiable work?
In England it is notifiable building work. A registered installer can normally self-certify it under a competent person scheme.